Keep Cool, Saving Fuel

Avionics / Crew Cooling / VIP

Helicopter / Corporate Aircraft (FAA STC/PMA)

10,000 BTU Module

10,000 BTU Module

28 VDC

20"L x 14.5 W x 12"H 55lbs

NASI Supplemental Air Conditioning System Cool
Anywhere Anytime (FAA STC/PMA)

10,800 BTU Module

10,800 BTU Module

400 Hz, 3 ph, AC

13.5"L x 15 W x 20.5"H 54lbs

Aircraft Ground Cooling (72,000 BTU) (Custom)

72,000 BTU Ground Cooling

72,000 BTU (6 Ton) Aircraft Cooling Module

Operates on 50/60 Hz 220 VAC or 400 Hz 200 VAC

36"L x 30"W x 40"H 460lbs

Contact NASI For More Information

B747 PACK FCS / Cool Projects (FAA-STC PMA)

Safety - Reliability - Fuel Economy

The B747 PACK FCS removes one of three air cycle machines & uses the passive air to air treatment portion of the pack to deliver conditioned air.

B747 PACK FCS

B747 PACK FCS — Flow Control System

General

B747

The NASI PACK Flow Control System (FCS) is a passive air-to-air treatment of cabin pressurization air for improved pressurization system reliability. All existing temp controls, ram air inlet, exit doors and heat exchanger operating as originally designed with improved airflow, reliability, range of temperature output and economy. The NASI PACK FCS is installed with couplers and clamps, no part modification.

Rotables removed are usable on PACKs 2 & 3, instant spares inventory worth three times the NASI PACK FCS cost.

Reliability is improved. The NASI PACK FCS System components last a lifetime without failure. Improved reliability with reduced collaterally damaged, degraded or impacted components. For example:

  • Extended heat exchanger life (with NASI the secondary side of the heat exchanger operating temperature is 200-300 F cooler).
  • Ram air exit door louvers do not seize from high temperature compressor exhaust.
  • No pie valves to ingest through an ACM or into a heat exchanger.
  • Improved reliability with, reduced load on the APU.
  • In hot climate #2 & #3 ACM's operate more efficient with a reduced load on the APU.
  • Weight reduction. (Weight reduction is fuel savings.)

NASI-ECO · Fuel Economy

B747 National PACK ECO Mod (ECO)

Fuel Economy

Increase reliability and reduce cost. Intelligent PACK control with NASI B747 PACK FCS-ECO reduces high cost PACK operation by 1/3. The Intelligent NASI FCS-ECO Module maintains optimum fuel economy, reducing fuel burn by 236 pounds/hour (35.2 gal/hr.) while improving Engine Pressure Ratio (EPR).

Improve PACK System Reliability and save Fuel

MD-11 National Intelligent PACK System (NIPS) for system reliability and fuel economy. Increase reliability and reduce cost with NASI MD-11 National Intelligent PACK System (NIPS). The NIPS Module maintains optimum fuel economy operation reduces fuel burn by 140 pounds/hour (20.9 gal/hr.) with GE power and 233 pounds/hour (34.78 gal/hr) with PW power while improving Engine Power Ratio (EPR).

NTEC-60SE C-130 / L-100 Supplemental Rapid Cooling System (SRCS)

With Super Enhancement

NTEC-60SE Overview

The NASI Super Enhancement includes high output A&B evaporator blowers increasing cooling airflow.

1) The Super Enhancement A system provides flight deck cooling air through gaspers mounted in the instrument panel, below the Navigators table and the upper fwd inbd side of the galley.

2) The Super Enhanced B system delivers cooler air with increased airflow to the instrument panel, avionics, and Electronic Flight Bags.

NTEC-60SE unit

Flight Deck Cooling and Heating / Cool Work

NASI's Legacy systems approved to 20,000 feet ASL. Supplementing ship heating and cooling on hundreds of transport aircrafts.